 200438

2-1

System inspection with DAVIE XD

ABS-D AND ABS/ASR-E

DAVIE XD diagnostics manual 

10

2. SYSTEM INSPECTION WITH DAVIE XD

2.1 GENERAL

If DAVIE is being used to communicate with the 

ABS/ASR electronic unit, the following points 

need to be taken into account:

If ABS valve failures occur while driving, the fault 

lamp will go out after switching the vehicle ignition 

off and on if the fault is no longer active.

Should faults occur with the wheel speed sensors 

while driving, switch the vehicle ignition off and 

on; the fault lamp should then remain on if the 

fault is no longer present.

The fault lamp will not go out until the vehicle has 

reached a speed of at least 7 km/h.

If DAVIE XD has been used to erase faults from 

the memory of the electronic unit, the fault lamp 

will go out when the vehicle has reached a speed 

of at least 7 km/h. 

In some "direct test" functions, it is possible to 

drive the vehicle while communications are taking 

place between DAVIE XD and the ABS/ASR unit. 

With the remaining "direct test" functions, 

communications between DAVIE XD and the 

electronic unit will be interrupted.

If a new ABS/ASR electronic unit is fitted, the unit 

will "recognise" whether the vehicle has an ASR 

system when the vehicle ignition is switched on. 

If an electronic unit is subsequently fitted in a 

vehicle that does not have an ASR system, the 

unit will always output ASR error messages. 

Whenever an ABS/ASR electronic unit is 

replaced, it is therefore important to reset the unit 

using DAVIE/XD.

ABS-D AND ABS/ASR-E

2-2

©

 200438

System inspection with DAVIE XD

10

DAVIE XD diagnostics manual

D3LC (ACH-EA)

2

©

 200438

Contents

11

DAVIE XD diagnostics manual

 

 

 

 

 

 

 

Content   ..  196  197  198  199   ..