Chrysler Sebring, Stratus sedan, Sebring Convertible. Manual - part 110

 

  Index      Chrysler     Chrysler Sebring, Stratus sedan, Sebring Convertible - service repair manual 2001-2007 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  108  109  110  111   ..

 

 

Chrysler Sebring, Stratus sedan, Sebring Convertible. Manual - part 110

 

 

TEST

ACTION

APPLICABILITY

3

Disconnect the Body Control Module C4 connector.
Disconnect the Power Top Switch connector.
Measure the voltage of the Convertible Top Switch Mux circuit to ground.
Is there any voltage present?

All

Yes

→ Repair the Convertible Top Switch Mux wire for a short to battery.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace Convertible Top Switch.

Perform BODY VERIFICATION TEST - VER 1.

4

Disconnect the Body Control Module C4 connector.
Measure the resistance between ground and the Convertible Top Switch Mux circuit.
Is the resistance between 4500.0 and 4900,0 ohms?

All

Yes

→ Replace the Body Control Module.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 5

5

Disconnect the Power Top Switch connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit in the Power
Top Switch connector.
Does the test light illuminate brightly?

All

Yes

→ Go To 6

No

→ Repair the Ground circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

6

Disconnect the Body Control Module C4 connector.
Disconnect the Power Top Switch connector.
Measure the resistance of the Convertible Top Switch Mux circuit from the BCM C4
connector to the Power Top Switch connector.
Is the resistance below 5.0 ohms?

All

Yes

→ Go To 7

No

→ Repair the Convertible Top Switch Mux wire for an open.

Perform BODY VERIFICATION TEST - VER 1.

7

If there are no possible causes remaining, view repair.

All

Repair

Replace the Convertible Top Switch.
Perform BODY VERIFICATION TEST - VER 1.

425

POWER TOP

POWER TOP SWITCH OPEN OR SHORTED TO BATTERY —

Continued

Symptom:

POWER TOP SWITCH SHORTED TO GROUND

When Monitored and Set Condition:

POWER TOP SWITCH SHORTED TO GROUND

When Monitored:

Whenever the ignition is on.

Set Condition:

Normal power top switch voltage is approximately 1.0 to 11.5 volts. When

the BCM senses voltage under 1.0 volts for over 10 seconds, this code will set.

POSSIBLE CAUSES

DTC PRESENT

POWER TOP SWITCH SHORTED TO GROUND

CONVERTIBLE TOP SWITCH MUX WIRE SHORT TO GROUND

BODY CONTROL MODULE - CONVERTIBLE TOP SWITCH MUX SHORT TO GROUND

TEST

ACTION

APPLICABILITY

1

With the DRBIII

t, erase DTCs.

Turn the ignition on.
Operate the power top in all positions including the 4 window drop position.
With the DRBIII

t, read DTCs.

Does the DRBIII

t display POWER TOP SWITCH SHORTED TO GROUND?

All

Yes

→ Go To 2

No

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors for a possible intermittent short to ground.
Perform BODY VERIFICATION TEST - VER 1.

2

Disconnect the Power Top Switch connector.
With the DRBIII

t, erase DTCs.

Cycle the ignition switch from OFF to ON.
With the DRBIII

t, read DTCs.

Does the DRBIII

t display POWER TOP SWITCH SHORTED TO GROUND?

All

Yes

→ Go To 3

No

→ Replace the Power Top Switch.

Perform BODY VERIFICATION TEST - VER 1.

3

Disconnect the Body Control Module C4 connector.
Disconnect the Power Top Switch connector.
Measure the resistance between ground and the Convertible Top Switch Mux circuit.
Is the resistance below 100.0 ohms?

All

Yes

→ Repair the Convertible Top Switch Mux wire for a short to ground.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 4

426

POWER TOP

TEST

ACTION

APPLICABILITY

4

If there are no possible causes remaining, view repair.

All

Repair

Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.

427

POWER TOP

POWER TOP SWITCH SHORTED TO GROUND —

Continued

Symptom:

POWER TOP SWITCH STUCK

When Monitored and Set Condition:

POWER TOP SWITCH STUCK

When Monitored:

Whenever the ignition is on.

Set Condition:

Normal operation of this switch consists of pressing it for only a few

seconds. If the BCM detects the switch stuck in a depressed condition for more than 28
seconds, this code will set and the BCM will ignore the input until the condition is
corrected.

POSSIBLE CAUSES

DTC PRESENT

POWER TOP SWITCH STUCK

CONVERTIBLE TOP SWITCH MUX WIRE SHORT TO GROUND

BODY CONTROL MODULE - CONVERTIBLE TOP SWITCH MUX

TEST

ACTION

APPLICABILITY

1

With the DRBIII

t, erase DTCs.

Turn the ignition on.
Operate the power top in all positions including the 4 window drop position.
With the DRBIII

t, read DTCs.

Does the DRBIII

t display POWER TOP SWITCH STUCK?

All

Yes

→ Go To 2

No

→ Check the switch for a possible sticking condition. Using the

wiring diagram/schematic as a guide, inspect the wiring and
connectors for a possible intermittent short to ground.
Perform BODY VERIFICATION TEST - VER 1.

2

Disconnect the Power Top Switch connector.
With the DRBIII

t, erase DTCs.

Cycle the ignition switch from OFF to ON.
Wait one minute.
With the DRBIII

t, read DTCs.

Does the DRBIII

t display POWER TOP SWITCH STUCK?

All

Yes

→ Go To 3

No

→ Replace the Power Top Switch.

Perform BODY VERIFICATION TEST - VER 1.

428