TEST
ACTION
APPLICABILITY
4
Disconnect the Sliding Door Control Module C2 connector.
Measure the resistance between the Ground circuit (cavity 20) and the Full Open
Switch Sense circuit in the Sliding Door Module connector.
Open the sliding door completely then partially close it. Repeat this step while
observing the ohmmeter.
Did the resistance change from below 15 ohms to above 1000.0 ohms when the door
was moved.
All
Yes
→ Replace the Power Sliding Door Module.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 5
5
Disconnect the Sliding Door Control Module C2 connector.
Disconnect the Full open Switch Sense wire at the lower drive unit.
Measure the resistance of the Ground wires between the PSD C2 connector (cavity
20) and the Full Open Switch connector.
Wiggle the harness while observing the ohmmeter.
Is the resistance below 5.0 ohms?
All
Yes
→ Go To 6
No
→ Repair the Ground wire for an open.
Perform BODY VERIFICATION TEST - VER 1.
6
Disconnect the Sliding Door Control Module C2 connector.
Disconnect the Full open Switch Sense wire at the lower drive unit.
Measure the resistance of the Full Open Switch Sense wire between the PSD C2
connector and the Full Open Switch connector.
Is the resistance below 5.0 ohms?
All
Yes
→ Go To 7
No
→ Repair the Full Open Switch Sense wire for an open.
Perform BODY VERIFICATION TEST - VER 1.
7
Disconnect the Sliding Door Control Module C2 connector.
Disconnect the Full open Switch Sense wire at the lower drive unit.
Measure the resistance between ground and the Full Open Switch Sense circuit.
Is the resistance below 1000.0 ohms?
All
Yes
→ Repair the Full Open Switch Sense wire for a short to ground.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 8
8
If there are no possible causes remaining, view repair.
All
Repair
Replace the Full Open Switch (lower drive unit).
Perform BODY VERIFICATION TEST - VER 1.
1049
POWER DOORS - SLIDING
INCOMPLETE POWER CLOSE - LATCH FAILURE —
Continued