Symptom: INCOMPLETE LATCH RELEASE- OVERCURRENT When Monitored and Set Condition: INCOMPLETE LATCH RELEASE- OVERCURRENT When Monitored: Whenever the power sliding door is operating in the closing direction. Set Condition: The latch motor stall current of 6.2 amps was detected during a non-redundant release. The main causes of this code setting is some type of blockage POSSIBLE CAUSES DTC PRESENT BINDING DOOR FULL OPEN SWITCH STUCK LATCH ASSEMBLY TEST ACTION APPLICABILITY 1 With the DRBIII t, record and erase DTC’s. Turn the ignition off, wait 10 seconds, then turn the ignition on. t, read ACTIVE DTCs. Does the DRBIII t display INCOMPLETE LATCH RELEASE - OVER CURRENT? All Yes → Go To 2 No → Using the wiring diagram/schematic as a guide, inspect the wiring and connectors for an intermittent condition. Operate the 2 Examine the door for proper fit and alignment, lose/ hard or torn seals, worn teeth on All Yes → Refer to Service information for the related symptom(S). Perform BODY VERIFICATION TEST - VER 1. No → Go To 3 1037 POWER DOORS - SLIDING |