Symptom List: BLEND CALIBRATION FAULT - MTC Test Note: All symptoms listed above are diagnosed using the same tests. The title for the tests will be BLEND CALIBRATION FAULT - When Monitored and Set Condition: BLEND CALIBRATION FAULT - MTC When Monitored: When the HVAC Door Recalibration is executed. Set Condition: If the passenger blend door’s span is found outside the tolerance due to: open door actuator electrical circuits; a bad door actuator; broken door linkage; a bound up MODE CALIBRATION FAULT - MTC When Monitored: When the HVAC Door Recalibration is executed. Set Condition: If the mode door’s span is found outside the tolerance due to: open door actuator electrical circuits; a bad door actuator; broken door linkage; a bound up door; door REAR BLEND CALIBRATION FAULT - MTC When Monitored: When the HVAC Door Recalibration is executed. Set Condition: If the rear blend door’s span is found outside the tolerance due to: open door actuator electrical circuits; a bad door actuator; broken door linkage; a bound up door; REAR MODE CALIBRATION FAULT - MTC When Monitored: When the HVAC Door Recalibration is executed. Set Condition: If the rear mode door’s span is found outside the tolerance due to: open door actuator electrical circuits; a bad door actuator; broken door linkage; a bound up door; 649 HEATING & A/C |