Symptom:

INCOMPLETE POWER OPEN -TIME OUT

When Monitored and Set Condition:

INCOMPLETE POWER OPEN -TIME OUT

When Monitored:

Anytime the Power Liftgate is in a power open operation.

Set Condition:

If the unit takes longer than 20 seconds to complete the open cycle, this

code will set.

POSSIBLE CAUSES

DTC PRESENT

BINDING LIFTGATE

DRB OPERATING VOLTAGE LOW

LIFTGATE DRIVER CIRCUIT PARTIAL SHORT TO GROUND

MODULE VOLTAGE LOW

PLG MODULE

TEST

ACTION

APPLICABILITY

1

NOTE: When this code is set, the module will abort the power close cycle
and begin

(Clutch Pulsing(. This is where the module will cycle the Liftgate

Clutch Driver until the gate stops moving (based on Optical Sensor inputs).
With the DRBIII

t, record and erase DTC’s.

Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the power liftgate several times if possible.
With the DRBIII

t, read DTCs.

Does the DRBIII

t display INCOMPLETE POWER OPEN - TIME OUT?

All

Yes

→ Go To 2

No

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors for an intermittent condition. Operate the
liftgate several times and check for any binding conditions.
Perform BODY VERIFICATION TEST - VER 1.

2

Examine the liftgate for proper fit and alignment, or anything that would cause an
obstruction to proper operation.
Check the prop rods to ensure liftgate will self rise from approximately 1/4 open
position.
Manually operate the liftgate several times.
If necessary, manually operate the liftgate of a known good vehicle and notice the
effort needed to open it.
Does it take more effort to operate the liftgate of the disabled vehicle than it should?

All

Yes

→ Refer to Service information for the related symptom(s).

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 3

873

POWER DOORS - LIFTGATE

TEST

ACTION

APPLICABILITY

3

Disconnect the Liftgate Drive Unit C1 connector.
Measure the resistance between ground and the Liftgate Open Driver circuit.
Is the resistance below 1000.0 ohms?

All

Yes

→ Locate and repair the liftgate driver circuit for a partial short to

ground. It could be in either the Open or the Close circuit. If the
drive circuits are okay, replace the drive motor.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 4

4

NOTE: Test the battery to ensure it is fully charged and in good condition
before proceeding.
Turn the ignition off.
Turn all lights and accessories off.
NOTE: Ensure all the connectors are connected before proceeding with this
step.
With the DRBIII

t in 9Power Liftgate9 9Monitor Display9 9PCI Bus Info9 read the

9Battery Voltage9 and compare it to the 9PLG Bat Volts Input9.
NOTE: If the difference is greater than 0.5 volts, backprobe the Fused B(+)
at the module to verify.
Does the voltage vary more than 0.5 volts?

All

Yes

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors. Locate and repair the reason for the
voltage drop.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 5

5

Turn the ignition off.
Turn all lights and accessories off.
With the DRBIII

t in 9Power Liftgate99 9Monitor Display9 9PCI Bus Info9 read the

BATTERY VOLTAGE and compare it to the MODULE VOLTAGE.
Operate the power liftgate and observe the voltage difference.
NOTE: If the difference is greater than 1.6 volts, backprobe the Fused B(+)
at the module to verify.
Does the voltage vary more than 1.6 volts when the liftgate is operating??

All

Yes

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors. Locate and repair the reason for the
voltage drop.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the Power Liftgate Module.

Perform BODY VERIFICATION TEST - VER 1.

874

POWER DOORS - LIFTGATE

INCOMPLETE POWER OPEN -TIME OUT —

Continued

Symptom:

LIFTGATE WAKE UP OUTPUT SHORT TO VOLTAGE - BCM

When Monitored and Set Condition:

LIFTGATE WAKE UP OUTPUT SHORT TO VOLTAGE - BCM

When Monitored:

Anytime the Body Control Module is awake.

Set Condition:

If the BCM sense an over current signal on the Liftgate Module Wake Up

Signal circuit, this code will set.

POSSIBLE CAUSES

DTC PRESENT

BODY CONTROL MODULE - LIFTGATE WAKE UP OUTPUT SHORT TO VOLTAGE

LIFTGATE MODULE WAKE UP SIGNAL WIRE SHORT TO VOLTAGE

POWER LIFTGATE MODULE - LIFTGATE WAKE UP SIGNAL SHORT TO VOLTAGE

TEST

ACTION

APPLICABILITY

1

With the DRBIII

t, record and erase DTC’s.

Turn the ignition off, wait 1 minute then turn the ignition on.
Wait 10 seconds.
With the DRBIII

t, read DTCs.

Does the DRBIII

t display LIFTGATE WAKE UP OUTPUT SHORT TO VOLTAGE?

All

Yes

→ Go To 2

No

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors for an intermittent condition.
Perform BODY VERIFICATION TEST - VER 1.

2

Disconnect the BCM C3 connector.
Using a 12-volt test light connected to ground, check the Liftgate Module Wake Up
Signal circuit in the BCM C3 harness connector.
Did the test light illuminate?

All

Yes

→ Go To 3

No

→ Replace the Body Control Module.

Perform BODY VERIFICATION TEST - VER 1.

3

Disconnect the Body Control Module C3 connector.
Disconnect the Power Liftgate Module C2 connector.
Measure the voltage between the Liftgate Module Wake Up Signal circuit and
ground.
Is there any voltage present?

All

Yes

→ Repair the Liftgate Module Wake Up Signal wire for a short to

voltage.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the Power Liftgate Module.

Perform BODY VERIFICATION TEST - VER 1.

875

POWER DOORS - LIFTGATE

Symptom:

LOOPBACK TEST FAILURE

When Monitored and Set Condition:

LOOPBACK TEST FAILURE

When Monitored:

Anytime the Power Liftgate Module is awake.

Set Condition:

The Power Liftgate Module did not receive its own transmitted message

on the PCI bus back (loopback) for longer than 1 second.

POSSIBLE CAUSES

DTC PRESENT

POWER LIFTGATE MODULE

TEST

ACTION

APPLICABILITY

1

With the DRBIII

t, record and erase DTC’s.

Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the power liftgate several times from stop to stop if possible.
With the DRBIII

t, read ACTIVE DTCs.

Does the DRBIII

t display LOOPBACK TEST FAILURE?

All

Yes

→ Replace the Power Liftgate Module.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors for an intermittent condition. Operate the
door several times and check for any binding conditions.
Perform BODY VERIFICATION TEST - VER 1.

876

POWER DOORS - LIFTGATE

 

 

 

 

 

 

 