Chrysler Pacifica. Manual - part 159

 

  Index      Chrysler     Chrysler Pacifica - service repair manual 2005 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  157  158  159  160   ..

 

 

Chrysler Pacifica. Manual - part 159

 

 

TEST

ACTION

APPLICABILITY

3

Replace IPM Front Blower Fuse.
Turn the ignition on.
Press the A/C Heater Control’s power switch on.
Operate the blower in all speeds and modes.
Does the blower motor operate properly without blowing the fuse?

All

Yes

→ Refer to the wiring diagrams located in the service information to

help isolate a possible intermittent short to ground condition.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 4

4

Turn the ignition off.
Disconnect the Blower Motor Resistor Block C1 harness connector.
Measure the resistance between ground and the Fused Front Blower Motor Relay
Output circuit.
Is the resistance below 10K ohms?

All

Yes

→ Repair the Fused Front Blower Motor Relay Output circuit for a

short to ground. Replace IPM Front Blower Fuse.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 5

5

Turn the ignition off.
Disconnect the Blower Motor Resistor Block C1 harness connector.
Disconnect the Blower Motor Resistor Block C2 harness connector.
Measure the resistance between Blower Motor Resistor Block pin C2-1 and pins C2-2,
C1-2, C1-3, C1-5, and C1-6.
Is there continuity between pin C2-1 and any other pin?

All

Yes

→ Replace the Blower Motor Resistor Block in accordance with the

Service Information. Replace IPM Front Blower Fuse.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 6

6

Turn the ignition off.
Disconnect the Blower Motor Resistor Block C1 harness connector.
Disconnect the Blower Motor Resistor Block C2 harness connector.
Measure the resistance between Blower Motor Resistor Block pin C1-4 and pins C2-2,
C1-2, C1-3, C1-5, and C1-6.
Is there continuity between pin C1-4 and any other pin?

All

Yes

→ Replace the Blower Motor Resistor Block in accordance with the

Service Information. Replace IPM Front Blower Fuse.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the Blower Motor in accordance with the Service Infor-

mation. Replace IPM Front Blower Fuse.
Perform BODY VERIFICATION TEST - VER 1.

633

HEATING & A/C

*BLOWER MOTOR INOPERATIVE - MTC —

Continued

TEST

ACTION

APPLICABILITY

7

Ensure IPM Front Blower Fuse is installed.
Turn the ignition on.
Press the A/C Heater Control’s power switch on.
NOTE: The test light must illuminate brightly. Compare the brightness to
that of a direct connection to the battery.
Using a 12-volt test light connected to ground, back probe the Blower Supply circuit
in the Blower Motor Resistor Block C2 harness connector.
Does the test light illuminate brightly?

All

Yes

→ Go To 8

No

→ Go To 12

8

Turn the ignition off.
Using a jumper wire connected to ground, back probe the Blower Driver circuit in the
Blower Motor Resistor Block C2 harness connector.
Turn the ignition on.
Press the A/C Heater Control’s power switch on.
Does the blower motor run at high speed?

All

Yes

→ Go To 9

No

→ Replace the Blower Motor in accordance with the Service Infor-

mation.
Perform BODY VERIFICATION TEST - VER 1.

9

Turn the ignition off.
Disconnect the A/C Heater Control C2 harness connector.
Using a jumper wire connected to ground, back probe the Blower Motor High Driver
circuit in the A/C Heater Control C2 harness connector.
Turn the ignition on.
Press the A/C Heater Control’s power switch on.
Does the blower motor run at high speed?

All

Yes

→ Go To 10

No

→ Go To 11

10

Turn the ignition off.
Disconnect the A/C Heater Control C2 harness connector.
Measure the resistance of the Ground circuit between the A/C Heater Control C2
harness connector and ground.
Is the resistance below 5.0 ohms?

All

Yes

→ Replace the A/C Heater Control in accordance with the Service

Information.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Repair the Ground circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

634

HEATING & A/C

*BLOWER MOTOR INOPERATIVE - MTC —

Continued

TEST

ACTION

APPLICABILITY

11

Turn the ignition off.
Disconnect the A/C Heater Control C2 harness connector.
Disconnect the Blower Motor Resistor Block C1 harness connector.
Measure the resistance of the Blower Motor High Driver circuit between the A/C
Heater Control C2 harness connector and the Blower Motor Resistor Block C1
harness connector.
Is the resistance below 5.0 ohms?

All

Yes

→ Replace the Blower Motor Resistor Block in accordance with the

Service Information.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Repair the Blower Motor High Driver circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

12

Turn the ignition on.
Press the A/C Heater Control’s power switch on.
NOTE: The test light must illuminate brightly. Compare the brightness to
that of a direct connection to the battery.
Using a 12-volt test light connected to ground, back probe the Fused Front Blower
Motor Relay Output circuit in the Blower Motor Resistor Block C1 harness connector.
Does the test light illuminate brightly?

All

Yes

→ Replace the Blower Motor Resistor Block in accordance with the

Service Information.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 13

13

Turn the ignition off.
Remove the Front Blower Motor Relay from the IPM.
NOTE: The test light must illuminate brightly. Compare the brightness to
that of a direct connection to the battery.
Using a 12-volt test light connected to ground, probe cavity 30 of the Front Blower
Motor Relay connector.
Does the test light illuminate brightly?

All

Yes

→ Go To 14

No

→ Replace the Integrated Power Module (IPM) in accordance with

the Service Information.
Perform BODY VERIFICATION TEST - VER 1.

14

Turn the ignition off.
Remove the Front Blower Motor Relay from the IPM.
Remove IPM Front Blower Fuse.
Measure the resistance between cavity 87 of the Front Blower Motor Relay connector
and IPM Front Blower Fuse (power input cavity).
Is the resistance below 5.0 ohms?

All

Yes

→ Go To 15

No

→ Replace the Integrated Power Module (IPM) in accordance with

the Service Information.
Perform BODY VERIFICATION TEST - VER 1.

635

HEATING & A/C

*BLOWER MOTOR INOPERATIVE - MTC —

Continued

TEST

ACTION

APPLICABILITY

15

Turn the ignition off.
Make sure that the Front Blower Motor Relay is installed.
Remove IPM Front Blower Fuse.
Turn the ignition on.
Press the A/C Heater Control’s power switch on.
NOTE: The test light must illuminate brightly. Compare the brightness to
that of a direct connection to the battery.
Using a 12-volt test light connected to ground, probe IPM Front Blower Fuse (power
input cavity).
Does the test light illuminate brightly?

All

Yes

→ Go To 16

No

→ Replace the Front Blower Motor Relay in accordance with the

Service Information.
Perform BODY VERIFICATION TEST - VER 1.

16

Turn the ignition off.
Remove IPM Front Blower Fuse.
Disconnect the IPM C9 harness connector.
Measure the resistance between IPM Front Blower Fuse (power output cavity) and
cavity 8 of the IPM C9 connector (IPM side).
Is the resistance below 5.0 ohms?

All

Yes

→ Repair the Fused Front Blower Motor Relay Output circuit for an

open.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the Integrated Power Module (IPM) in accordance with

the Service Information.
Perform BODY VERIFICATION TEST - VER 1.

636

HEATING & A/C

*BLOWER MOTOR INOPERATIVE - MTC —

Continued

 

 

 

 

 

 

 

Content   ..  157  158  159  160   ..