TEST 10A REPAIRING AUTOMATIC (ROLLING) DOOR LOCKS Perform TEST 1A Before Proceeding *Perform Verification TEST VER-2A. **Check connectors - Clean / repair as necessary. WITH THE DRB ENTER DOES THE DRB "BODY COMPUTER" DISPLAY: NO WITH THE DRB, START TEST 10A. AND READ AUTO DOOR "AUTO DOOR LOCKS ENABLE AUTO DOOR LOCK STATUS (UNDER ARE ENABLED"? LOCKS.* MISCELLANEOUS). YES WITH THE DRB ENTER DOES THE DRB NOTE: ENSURE ALL "INPUT/OUTPUT" AND DISPLAY YES PERFORM "DOOR DOORS ARE CLOSED. READ THE DRIVER’S "DRDOOR AJAR: AJAR" TEST 1A. DOOR AJAR STATUS. CLOSED"? NO WITH THE DRB, READ ALL OTHER DOOR DOES THE DRB YES PERFORM "DOOR AJAR SWITCH DISPLAY ANY "DOOR AJAR" TEST 1A. STATES. AJAR: CLOSED"? NO WITH THE DRB, READ TURN IGNITION ON "PCI BUS ENGINE (ENGINE OFF). INFO" (UNDER "MONITORS"). DOES THE TPS THE TP SENSOR IS OBSERVE THE TPS PERCENTAGE NO INOPERATIVE. WHILE DEPRESSING INCREASE AS THE THE THROTTLE. THROTTLE IS DIAGNOSE USING... OPENED? YES THE APPROPRIATE "POWERTRAIN DIAGNOSTIC MANUAL". CONTINUE TEST PAGE. P O W E R D O R L O C S T E M 598 |