Chrysler New Yorker. Manual - part 442

 

  Index      Chrysler     Chrysler New Yorker - service repair manual 1997-1999 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  440  441  442  443   ..

 

 

Chrysler New Yorker. Manual - part 442

 

 

TEST 19A

CONTINUED - REPAIRING DOOR AJAR INDICATOR

NOTES

I

N

S

T

R
U

M

E

N

T

C

L

U

S

T

E

R

366

TEST 19A

CONTINUED - REPAIRING DOOR AJAR INDICATOR

*Perform Verification TEST VER-2A.

**Check connectors - Clean / repair as necessary.

TEST 19A

CONTINUED FROM 

MAKE SURE ALL

THE PREVIOUS DOORS ARE CLOSED.

PAGE.

WITH THE DRB ENTER

DOES THE DRB

"BODY COMPUTER" THEN DISPLAY BOTH 

DOOR 

NO 

PERFORM "DOOR

"INPUT/OUTPUT" AND

AJAR STATES 

AJAR" TEST 1A.

READ THE DOOR AJAR 

"OPEN"?

STATES.

YES

REPLACE THE

INSTRUMENT 
CLUSTER.*

I

N

S

T

R
U

M

E

N

T

C

L

U

S

T

E

R

367

TEST 20A

REPAIRING TRUNK AJAR INDICATOR

Perform TEST 1A Before Proceeding

FIG. 1

FIG. 2

FIG. 3

I

N

S

T

R
U

M

E

N

T

C

L

U

S

T

E

R

368

TEST 20A

REPAIRING TRUNK AJAR INDICATOR

Perform TEST 1A Before Proceeding

*Perform Verification TEST VER-2A.

**Check connectors - Clean / repair as necessary.

ENSURE THAT THE
TRUNK IS ALIGNED

START TEST 20A. 

PROPERLY AND FULLY

CLOSED.

TURN IGNITION ON 

DID THE TRUNK AJAR 

YES

CONTINUE TEST 

(ENGINE OFF).

INDICATOR

20A ON THE NEXT 

ILLUMINATE?

PAGE.

NO 

OPEN TRUNK AND

DID THE TRUNK AJAR  YES

SYSTEM IS 

OBSERVE THE TRUNK

INDICATOR

OPERATING PROPERLY 

AJAR INDICATOR. 

ILLUMINATE?

AT THIS TIME.* 

NO 

KEY OFF. DISCONNECCT

CONNECT A JUMPER 

THE DECKLID RELEASE

WIRE BETWEEN GROUND 

DID THE TRUNK AJAR  YES

REPLACE THE

SOLENOID/DECKLID AND THE DECKLID AJAR 

INDICATOR

DECKLID AJAR 

AJAR HARNESS

SWITCH SENSE CKT. 

ILLUMINATE?

SWITCH.* 

CONNECTOR.** FIG. 

1

NO 

WITH JUMPER WIRE 

USING AN OHMMETER,

REPAIR THE OPEN 

STILL CONNECTED. MEASURE BETWEEN

IS 

THE RESISTANCE 

NO 

DECKLID AJAR 

DISCONNECT THE

GROUND AND THE

BELOW 5.0 OHMS?

SWITCH SENSE

INSTRUMENT CLUSTER

DECKLID AJAR SWITCH 

CIRCUIT.*

C2 HARNESS CONN.**

SENSE CKT. FIG. 2

YES

DISCONNECT THE

USING A VOLTMETER, 

INSTRUMENT CLUSTER

MEASURE THE FUSED

IS THE VOLTAGE

YES

REPLACE THE

C1 HARNESS

B (+) CIRCUIT

ABOVE 10.0 VOLTS? 

INSTRUMENT 

CONNECTOR.** (CAVITY 3).

CLUSTER.*

FIG. 3

NO 

REPAIR THE OPEN 

FUSED B(+) 
CIRCUIT.*

I

N

S

T

R
U

M

E

N

T

C

L

U

S

T

E

R

369

 

 

 

 

 

 

 

Content   ..  440  441  442  443   ..