TEST 7A

REPAIRING

(

EVAPORATOR TEMPERATURE SENSOR FAILURE

(

TROUBLE CODE

Perform TEST 1B Before Proceeding

FIG. 1

FIG. 2

A
U

T

O

M

A

T

I

C

T

E

M

P
E

R
A

T

U
R

E

C

O

N

T

R

O

L

S
Y
S

T

E

M

138

TEST 7A

REPAIRING

(

EVAPORATOR TEMPERATURE SENSOR FAILURE

(

TROUBLE CODE

Perform TEST 1B Before Proceeding

*Perform Verification TEST VER-2A.

**Check connectors - Clean / repair as necessary.

USING THE DRB ENTER

"SENSORS" AND READ 

IS THE VOLTAGE

NO 

CONTINUE TEST 

START TEST 7A.

THE EVAPORATOR 

ABOVE 5.2 VOLTS? 

7A ON THE NEXT 

TEMPERATURE SENSOR PAGE.

VOLTAGE. 

YES

DISCONNECT THE

USING A VOLTMETER, 

REPAIR THE EVAP 

EVAPORATOR 

MEASURE THE EVAP 

IS THE VOLTAGE

YES

TEMP SENSOR SIGNAL 

TEMPERATURE SENSOR 

TEMP SENSOR SIGNAL 

ABOVE 5.3 VOLTS? 

CKT FOR A SHORT TO 

HARNESS CONNECTOR.** 

CKT. 

VOLTAGE. IF OK,

SEE GENERAL INFO 4.0

FIG. 1

REPLACE BCM.*

NO 

CONNECT A JUMPER 

WITH THE DRB, READ 

REPLACE THE

WIRE BETWEEN THE

THE EVAPORATOR 

IS THE VOLTAGE

NO 

EVAPORATOR 

EVAP TEMP SENSOR 

TEMPERATURE SENSOR 

ABOVE 4.9 VOLTS? 

TEMPERATURE

SIGNAL & SENSOR 

VOLTAGE. 

SENSOR.* 

GND CKTS. FIG. 1

YES

CONNECT A JUMPER 

WITH THE DRB, READ 

WIRE BETWEEN THE

THE EVAPORATOR 

IS THE VOLTAGE

NO 

REPAIR THE OPEN 

EVAP TEMP SENSOR 

TEMPERATURE SENSOR 

ABOVE 4.9 VOLTS? 

GROUND CIRCUIT.*

SIGNAL CKT AND

VOLTAGE. 

GROUND. FIG. 1

YES

DISCONNECT THE BODY 

USING AN OHMMETER,

CONTROL MODULE C2 

MEASURE THE

HARNESS CONNECTOR.** EVAPORATOR 

TEMP 

SENSOR SIGNAL 

SEE GENERAL INFO 4.0

CIRCUIT... 

BETWEEN THE BCM AND

REPAIR THE OPEN 

THE EVAPORATOR 

IS 

THE RESISTANCE NO EVAPORATOR 

TEMP 

TEMPERATURE SENSOR.

BELOW 5.0 OHMS?

SENSOR SIGNAL 

CIRCUIT.*

FIGS. 1 & 2

YES

REPLACE THE BODY 
CONTROL MODULE.* 

A
U

T

O

M

A

T

I

C

T

E

M

P
E

R
A

T

U
R

E

C

O

N

T

R

O

L

S
Y
S

T

E

M

139

TEST 7A

CONTINUED - REPAIRING

(

EVAPORATOR TEMPERATURE SENSOR FAILURE

(

TROUBLE CODE

FIG. 1

A
U

T

O

M

A

T

I

C

T

E

M

P
E

R
A

T

U
R

E

C

O

N

T

R

O

L

S
Y
S

T

E

M

140

TEST 7A

CONTINUED - REPAIRING

(

EVAPORATOR TEMPERATURE SENSOR FAILURE

(

TROUBLE CODE

*Perform Verification TEST VER-2A.

**Check connectors - Clean / repair as necessary.

TEST 7A DISCONNECT 

THE

CONTINUED FROM EVAPORATOR 

THE PREVIOUS TEMPERATURE SENSOR 

PAGE.

HARNESS CONN.**

SEE GENERAL INFO 4.0

WITH THE DRB, READ 

THE EVAPORATOR 

IS THE VOLTAGE

YES

CONTINUE TEST 

TEMPERATURE SENSOR ABOVE 4.9 VOLTS? 

7A 

ON THE NEXT 

VOLTAGE. 

PAGE.

NO 

KEY OFF. DISCONNECT 

USING AN OHMMETER,

REPAIR THE

THE BODY CONTROL

MEASURE BETWEEN

IS THE RESISTANCE 

YES

EVAPORATOR 

MODULE C2 HARNESS

GROUND THE EVAP 

BELOW 5.0 OHMS?

TEMPERATURE SENSOR 

CONNECTOR.** 

TEMP SENSOR SIGNAL 

SIGNAL CIRCUIT FOR A

SEE GENERAL INFO 4.0

CKT. FIG. 1

SHORT TO GROUND.* 

NO 

WITH AN OHMMETER,

TEMPERATURE SENSOR 

REPAIR THE EVAP TEMP 

MEASURE BETWEEN

SIGNAL CIRCUIT. 

IS THE RESISTANCE 

YES

SENSOR SIGNAL 

THE SENSOR GROUND 

BELOW 5.0 OHMS?

CIRCUIT FOR A SHORT

CIRCUIT AND THE

TO THE SENSOR GROUND 