Fig. 74: Checking For Continuity Between The No. 2 Terminal Of The Condenser Fan Relay 11. Check for continuity between the No. 1 terminal of the condenser fan 2P connector and body ground. Is there continuity? YES: Replace the condenser fan motor. NO: Check for an open in the wire between the condenser fan and body ground. If the wire is
2004 Acura TSX 2004 AUTOMATIC A/C SYSTEMS Climate Control System - TSX
|