Standard (New): 0.15-0.35 mm (0.006-0.014 in) Service Limit: 0.40 mm (0.016 in.) Fig. 183: Measuring The Connecting Rod End Play 4. If the connecting rod end play is out-of-tolerance, install a NEW connecting rod, and recheck. If it is still out-of-tolerance; replace the crankshaft (see CRANKSHAFT & PISTON REMOVAL ). 5. Push the crankshaft firmly away from the dial indicator, and zero the dial against the end of the crankshaft. Then pull the crankshaft firmly back toward the indicator; the dial reading should not exceed Crankshaft End Play: Standard (New): 0.10-0.35 mm (0.004-0.014 in.) Service Limit: 0.45 mm (0.018 in.)
2004 Acura TSX 2004 ENGINES 2.4L DOHC VTEC - TSX
|